Our PAROC insulated panels for new build applications are high-class steel-faced sandwich panels with a core of stone wool.
We provide solutions for facilities with individual requirements, such as extra fire-safety, hygiene, sensitive acoustics, and modern architecture. Sandwich panel solutions include everything needed to complete a structure: panels, fixings, flashings, profiles, sealants, lifting equipment as well as first-class technical support.



* Does not apply to Paroc Print (C-s1,d0)
  • Fire resistance: Up to 4 hours
  • Reaction to fire: Euroclass A2-s1,d0*
  • FM approvals: FM4880, FM4881
  • Long span
  • Modular width standard: 1200 mm (cover width 1196 mm)
  • Steel thicknesses: 0.5-0.7 mm externally and internally

New build projects

Technical Details - Insulated panels for new build

Stone wool core
Profiles
Coatings & colours
Properties
Our stone wool sandwich panels are based on our Advanced Structural Technology (AST) and high quality PAROC structural stone wool. The panels come in four panel types, each with different technical properties:
AST® S: for normal use in buildings with moderate fire requirements
AST® F: for high fire requirements
AST® E for high strength requirements.
AST® T for walls with high termal insulation requirement
AST® L for wall with extremally high thermal insulation requirement
 
Read more about AST and our stone wool
Download the AST brochure
Download the technical guide
 

Smooth

Paroc_Panel_paroc-smooth-panel-models (1)
The flat profile is a modern solution

Profile: Smooth

Minimum thickness: 80 mm

Reference: Europcar Logistic Centre, Finland

Shadow

Paroc_Panel_paroc-smooth-panel-models (1)

Looking to highlight the play between light and shadow in the panel joints?
Then your choice is PAROC® shadow panel.

Profile: Shadow

Minimum thickness: 80 mm

Reference: Clarks Distribution Centre, UK

Line

Paroc_Panel_paroc-line-panel-models

The Line profile forms an elegant streamline effect. The distance between the lines can be varied according to your requirements.

Profile: Line

Distances: 150 mm, 200mm, 600mm

Reference: L90 Power Plant, Denmark

Micro

Paroc_Panel_Micro_2

For subtle shading, try PAROC® micro.
Profile: Micro

Reference: Kupittaa Sports Arena, Finland

Micro / Line

paroc_panel_micro_render

Combine these alternatives to get a unique impression

Profile: Micro/Line

Fire rating: Euroclass C-s1,d0

Reference: Fjeld Blomster​, Norway

Acoustic

Paroc_Panel_paroc-print-gallery

Internal walls with high absorbtion and reduction

Profile: Acoustic

Fire rating: Euroclass C-s1,d0

More: Acoustic Applications

Print

Paroc_Panel_paroc-print-gallery

The Print profile allows you to print any pattern such as logos, images or drawings to your stone wool insulated panel.

Profile: Print

Fire rating: Euroclass C-s1,d0

Reference: Wall of Poetry, Finland

Delign

Paroc_Panel_paroc-print-gallery

PAROC Delign is a new and innovative sandwich panel system that can be used to fade out the vertical joints typically found on facades of prefabricated buildings.

Profile: Delign

Fire rating: Euroclass C-s1,d0

More about: Architectural DELIGN

Coating external: PVDF, PE or matte PVDF

Coating internal: Polyester or FoodSafe/Stainless steel for hygienic applications

Colours: Standard and special. Download our colour guide

Download the technical guide

Download Product Selector 2018
 

External walls and partitions

Panel
type
Panel property Nominal / Actual Thickness, mm
50/53 80/79 100/99 120/120 150/151 175/173 200/202 240/243 300/305 
AST® L U-value, W/m2K 1) - 0,45 0,37 0,30 0,24 0,21 0,18 0,15 0,12
Fire rating, 
horizontal/vertical, min 
2)
- - - - EI120 / EI180 EI120 / EI180 EI120 / EI180 EI120 / EI180 EI120 / EI180
AST® T U-value, W/m2K 1) - 0,47 0,38 0,31 0,25 0,22 0,19 0,16 0,13
Fire rating, 
horizontal/vertical, min 
2)
- EI 30/
EI 30
EI 45/
EI 45
EI 60/
EI 90
EI 60/
EI 120
EI 180/
EI 180
EI 180/
EI 180
EI 240/
EI 240
EI 240/
EI 240
AST® S U-value, W/m2K 1) - 0,48 0,38 0,32 0,26 0,22 0,19 0,16 0,13
Fire rating, 
horizontal/vertical, min 
2)
- EI 30/
EI 30
EI 60/
EI 60
EI 90/
EI 90
EI 180
EI 180
EI 180/
EI 180
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240
AST®S+ U-value, W/m2K 1) - 0,38  0,32 -
Fire rating, 
horizontal/vertical, min 
2)
- - EI 120/
EI 120
EI 120/
EI 120
- -
AST® F U-value, W/m2K 1) - 0,53 0,43 0,36 0,29 0,25 0,22 0,18 0,14
Fire rating, 
horizontal/vertical, min 
2)
- EI 45/
EI 90
EI 45/
EI 120
EI 45/
EI 120
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240
AST®F+ U-value, W/m2K 1) - 0,43 0,36 
Fire rating, 
horizontal/vertical, min 
2)
- EI 120/
EI 120
EI 120/
EI 120
-
AST® E U-value, W/m2K 1) 0,77 0,53 0,43 0,36 0,29 0,25 0,22 0,18 0,14
Fire rating, 
horizontal/vertical, min 
2)
EI 45/
EI 45
EI 45/
EI 90
EI 45/
EI 120
EI 45/
EI 120
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240
EI 240/
EI 240

NPD = no performance determined (not tested)
   -   = not available

  1. U-values including surface resistance Rsi + Rse = 0.17 m2K/W and the influence of joints.
  2. Structure design and allowed spans according to the Design Guideline. PAROC® acoustic panels do not have a fire endurance classification, PAROC® print and PAROC® art panels have been classified in Euroclass C-s1,d0. Additional information regarding details and allowed spans is available from the Paroc Panel System technical support.
  3. Valid for standard surface panels.

External walls PAROC Shadow® panel, fire rating

Panel
type
Panel property Nominal / Actual Thickness, mm
80/79 100/99 120/120 150151 175/173 200/202 240/243 300/305 
AST® L
AST® S
AST
® F
AST
® E
Fire rating, 
horizontal/vertical, min 
2)
NPD EI180/- EI180/- EI180/-

Ceilings

Panel
type
Panel property Nominal / Actual Thickness, mm
50/53 80/79 100/99 120/120 150/151 175/173 200/202 240/243 300/305 
AST® E U-value, W/m2K 1) 0,77 0,53 0,43 0,36 0,29 0,25 0,22 0,18 0,14
Fire rating, 
ceilings
NPD NPD EI 60 EI 60 EI 90 EI 90 EI 90 EI 90 EI 90
  Weight, kg/m2 3) 16 19 22 24 28 31 34 39 47

NPD = no performance determined (not tested)

  1. U-values including surface resistance Rsi + Rse = 0.17 m2K/W and the influence of joints.
  2. Structure design and allowed spans according to the Design Guideline. PAROC® acoustic panels do not have a fire endurance classification, PAROC® print and PAROC® art panels have been classified in Euroclass C-s1,d0. Additional information regarding details and allowed spans is available from the Paroc Panel System technical support.
  3. Valid for standard surface panels.

Downloads - insulated panels for new build

Design Tools
Installation & Use
Certificates & Approvals

Product Selector 2018

Paroc Panels - Colour Indications

Paroc Panels - Technical Guide

Paroc Panels - Installation guide

Paroc Panels - Use and maintenance guide

Paroc Panels - Installation guide

Environmental Declaration PS

ISO 9001:2015 Certificate

ISO 14001:2015 Certificate

Environmental Declaration PS

Environmental Declaration PS-2

Environmental Declaration PS-3

Complementary products

We use cookies on our website www.parocpanels.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click “Accept and close” to accept the use of cookies on our website. If you do not click “Accept and close” but continue to use this website: you thereby consent to the use of all EcoTherm Insulation cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.